Page 69 - TesaKatalogen
P. 69
E x ter n al M i c r o meters Maximum
permissible error
INTERAPID Setting Standards over the length:
± (1 + L/100) μm,
02140001 mm 02140011 mm L in mm
02140002 02140012 275 Hardened steel
02140003 25 02140013 300 Inspection report
02140004 50 02140014 325 with actual
02140005 75 02140015 350 measured length
02140006 100 02140016 375 Cylindrical gauge
02140007 125 02140017 400 block with plastic
02140008 150 02140018 425 insulating grip and
02140009 175 02140019 450 dull chrome shaft
02140010 200 02140020 475 Two measuring
225 500 faces, flat and
250 rounded
With lengths:
Measuring range up to 1500 mm also available upon request. ≤ 175 mm= 10 mm.
≥ 200 mm = 13 mm.
ETALON Cylindrical Step Gauges
Maximum
For adjustement of the display and calibration. permissible errors for
nominal diameters:
≤ 80 mm = 1,5 μm
≥ 90 ≤ 120 mm =
2,0 μm ≥ 130 mm
= 2,5 μm
Alloyed steel,
hardened
Diameters in steps
of 5 mm (≤ 50 mm)
or 10 mm (> 50 mm).
072112020 mm
072112021
5 ÷ 100
5 ÷ 150
Guide Collars for Setting Standards
Making the positioning of INTERAPID setting standards quick and easy.
02140103 mm mm
02140108 100 ÷ 175 8
200 ÷ 1475 8
C-20