Page 19 - TesaKatalogen
P. 19
C o n n ecti v it y 180 x 180 x 84 mm
(W x D x H)
TESA Portable SPC PRINTER Paper width:
110 mm. Print mode:
TESA portable intelligent printer designed for the inspection of finished parts or 40 signs/line
incoming goods – Provides SPC statistics and prints out measurement results RS232 for data
with graphical representations. inputs (9-pin male,
The TESA SPC PRINTER can be connected not only to TESA measuring instru- trapezoid connector)
ments, but also to those provided with a DIGIMATIC output – Your TESA SPC DIGIMATIC (Ansley
PRINTER is capable of recognising the plug in tool and will execute the appro- connector, 10-pin)
priate configuration automatically. Connector with
mini-jack for remote
TESA SPC Printer triggering of data
transfer
Mains adapter 100
to 240 Vac, 6,6 Vdc.
Optional accessory:
6 V rechargeable
battery pack.
IP40 (IEC 60529)
EN 50081-1, EN
50081-2, EN 50082-
1, EN 50082-2
–– Memory capacity : 9999 single va- 06430000 SPC PRINTER EU
lues for one feature per sample. Portable. With memory, SPC, value classification
and graphs. RS232 interface
–– Two operating modes: “Normal” and
“Tolerance”. Delivered with the following accessories:
04765013 Roll of printer paper, width =
–– Limits of size quickly set on the dis-
play of the connected instrument 110 mm for TESA SPC Printer
with subsequent transfer to TESA 04761054 Mains adapter /battery charger 100 ÷ 240 VAC
PRINTER SPC.
50 ÷ 60 Hz, 6,6 Vdc, 750 mAh supplied without cable
–– Output of statistical values printed 04761055 EU Mains cable for 04761054 adapter
out with graphical representations.
Optional accessories:
–– Output of reports with headings to 04761056 USA Mains cable
be filled in by the operator. 04768035 Battery charger 6V, 0,5AH
–– Hardcopies printed in preferred
language (English, German, French,
Italian or Spanish).
–– Battery-powered (6 V) printer unit
for use on the move (optional).
"Normal" "Tolerance"
Mode Mode
–
Lower size limit (min.) –
Upper size limit (max.) –
Tolerance
Number of values taken: –
number of samples –
< smallest dimension –
> largest dimension
% out of tolerance –
Lowest value listed –
Highest value listed –
Dispersion R –
Arithmetical mean
Standard deviation sn, sn-1
Indication of capacity Cp, Cpk
Graphical representations:
Position of each single value within the tolerance zone (10 classes)
Graphical representations:
Histogrammes
Display (LED) - Classification of the value measured:
Green for pass, yellow for rework,red for reject
A-6