Page 56 - TesaKatalogen
P. 56
DIN 863 T3 M i c r o meters with a n al o g u e i n di c ati o n
(Style D14)
NF E 11-090 ETALON MICROSPEL 280
Meas. element:
max. perm. error These micrometers have a mobile anvil along with an 8 mm diameter clamping
of 2 μm bore for mounting a sensor with linear action such as a TESA GT 21/22 electronic
Mobile anvil: probe. Specially designed for batch inspection of small precision made parts.
repeatability
limit of
0,5 μm.
Tungsten carbide
tipped
Adjustable part
support (except
model with small
measuring faces).
0,5 mm
Anvil:
2 up to 8 N,
adjustable
6,5 mm or 2 mm dia.
and length of 5 mm
for models
with small
measuring faces.
Vernier reading
to 0,002 mm
5
ø2
mm
072110816 0 ÷ 25 Standard inserts
072110853 0 ÷ 20 Pointed inserts
Electronic probe and micrometer stand are not
part of the delivery scope and must be ordered
separately.
C-7