Page 290 - TesaKatalogen
P. 290
DIN 32876 P r obes with a x ial moveme n t , Ø 8 mm
Part 1
Nickel-plated hou- Standard Probes, ± 1 mm, 4,3 mm Travel (GT22)
sing. Stainless steel
measuring bolt, Universal probes for common but constraining applications.
hardened. Nitrile –– 8 mm diameter probe housing. Can be clamped over its entire length.
sealing bellows = –– Measuring bolt mounted on a ball bearing.
resistant elastomer –– Both the probe housing and ball-bearing guide are separate from one
Fixing shank
Ø 8 mm. Measuring another, so that the measuring bolt moves easily even if the probe is
bolt guided on not clamped appropriately.
ball-bearing. –– Degree of protection IP65 according to IEC 60529.
Distance from elec- –– Wide range of accessories including measuring inserts, spring sets, etc.
trical zero of both –– LVDT probes compatible with measuring equipment from other makers
stops is either ad- available on request.
justable (downward)
or depending on 21 82,5 ø 9,6
the position of the 47
lower stop (upward).
Interchangeable R 1,5
inserts. M2,5 thread.
Carbide ball tip ø 8h6 19
Ø 3 mm. 2 m long
cable. 5-pin DIN -1,2 +3
45322 connector. 0
Supply frequency:
13 kHz (± 5 %). Max GT 22 GT 22
mechanical fre-
quency** 60 Hz. 03210924 GT 22 Measuring Nominal Measuring bolt retrac- Sealing
0,15 μm/°C 03210921 GT 22 range, mm measuring tion bellows
03210922 GT 22 force*, N
20 ± 0,5°C 03210923 GT 22 ±1 Mechanical / vacuum Nitrile
03210925 GT 22 ±1 0,63 Mechanical / vacuum Nitrile
Protection level IP65 03210926 GT 22 ±1 0,16 Mechanical / vacuum Nitrile
(IEC 60529) 03210927 GT 22 ±1 0,25 Mechanical / vacuum Nitrile
03210928 GT 22 ±1 0,40 Mechanical Nitrile
Mobile weight: 6 g ±1 1,00 Mechanical Nitrile
Inspection report ±1 1,60 Mechanical Nitrile
with a declaration of ±1 2,50 Mechanical Nitrile
conformity 4,00
Measuring Max. permissible Repeata- Hysteresis, Setting of the lower Cable output Data Sheet
travel, mm error for deviations bility, μm μm bolt stop***, mm No.
4,3 in linearity, μm 03200250
(L in mm) (factory setting)
0,02 -2,2 to 0,1 (factory Radial
GT 22 0,2 + 3 · L3 0,01
setting -1,2)
* Electrical zero (N) ± 25 % deviation limit. Valid in vertical mounting position, measuring bolt lowered and in static measuring.
** For an amplitude of 10 % to the last value of the measuring range.
*** Distance from electrical zero.
O-17