P r obes with a x ial moveme n t , Ø 8 mm DIN 32876
Part 1
Standard Probes ± 5 mm, 10,3 mm Bolt Travel, Nickel-plated
Extended Range housing. Stainless
steel measuring
–– Designed for long measuring travels and low resolution of values bolt, hardened. Viton
–– Specially suited for use on multigauging inspection fixtures. bellows = highly
–– Correction factor appplied to get the true value is 2,5x resistant fluoroe-
lastomer
(10x for the S probe version). Fixing shank
–– Protection level IP 65 as per IEC 60529. Ø 8 mm. Measuring
–– Large choice of accessories: Measuring inserts, spring sets, etc. bolt guided on
–– LVDT probes compatible with measuring equipment from other suppliers also ball-bearing.
Distance from elec-
available on request. trical zero of both
stops is either ad-
GT 61 justable (downward)
or depending on
GT 62 the position of the
lower stop (upward).
29,5 110,7 GT61 Interchangeable
120 81 9 8 inserts. M2,5 thread.
Carbide ball tip
81 Ø 3 mm. 2 m long
cable. 5-pin DIN
67,2 45322 connector.
Supply frequency:
R 1,5 13 kHz (± 5 %) Max.
mechanical fre-
ø 8h6 ø3 quency** 60 Hz.
ø 9,6 127.5 0,09 μm/°C
GT611 20 ± 0,5°C
Protection level IP65
(IEC 60529)
Mobile weight: 8 g
Inspection report
with a declaration of
conformity
-5 +5 GT62
0
GT 61 / GT 62
03230041 GT 61 Measuring Nominal mea- Measuring bolt Sealing
03230042 GT 62 range, mm suring force*, N retraction bellows
±5 0,90 Mechanical Viton
±5 0,90 Mechanical / vacuum Viton
Measuring Max.permissible Repeata- Hysteresis, Measuring bolt***, Cable output Data Sheet
bolt travel, error for deviations bility, μm μm mm (factory No.
mm in linearity, μm 03200294
10,3 (L in mm) setting) 03200295
GT 61 10,3 1+4·L 0,05 0,05 Lower - 5,1 Axial
GT 62 (BPX: 0,2 + 0,8 · L) upper + 5,2
(factory setting -5)
1+4·L 0,05 0,05 Lower - 5,1 Radial
(BPX: 0,2 + 0,8 · L) upper + 5,2
(factory setting -5)
* Electrical zero (N) ± 25 % deviation limit. Valid in vertical mounting position, measuring bolt lowered and in static measuring.
** For an amplitude of 10 % to the last value of the measuring range.
*** Distance from electrical zero.