Page 308 - TesaKatalogen
P. 308

U S B , D C , W i r eless P r obes

DIN 32876                                 DC Miniature Probes ± 1 mm (Output Signal in V)
Part 1
                                          Probe provided with an electronic box which converts the signal to obtain an
See standard probes                       output DC voltage
technical data
Cable length: 2 m.                        Typically used for direct connection to a computer unit or an interface equipped
DIN 45322 plug                            with an analogue input
connector, 5 poles.
Use to connect to a                                                                                                                                                                                                                          1 +15V
device with an ana-                                                                                                                                                                                                                          2
log input. For more                                                                                                                                                                                                                          3 –15V
information, refer to
technical data for                                                                           M4
standard probes
Drive voltage: ± 15 V                                                                                                                                                                                                                        5 Signal
Consumption: 15 mA
Adjustment load:                          Connection of a DC probe to a computer, an interface or  DIN 5 pin connection schematic
> 1 kΩ. Can be used                       a plotter
in any position.
Special versions on                       Measuring Nominal mea- Bolt retraction                   Sealing            Output Sensitivity,
request. Sensivity:                       range, mm suring force*, N                               bellows            voltage, V V/mm
2 V/mm, 5 V/mm, 10                                                                                                    ±1 1
V/mm Output: 0 V à     03230085 GT 44 DC  ± 1 0,4  Mechanical / vacuum Viton
+10 V (max +10 V)
See standard probes
technical data

See standard probes
technical data

See standard probes
technical data

See standard probes
technical data

See standard probes
technical data

                       GT 44 DC           Measuring bolt travel, Max. permissible                  Repeatability, μm  Data sheet No.
                                          mm error for deviations in                               0,1                03200518

                                                                    linearity, μm
                                                                    (L en mm)
                                          2,1 0,2 + 5· L3

                       * Electrical zero (N) ± 25 % deviation limit. Valid in vertical mounting position, measuring bolt lowered and in static measuring.

                                                                                                                                                                                                                                                       O-35