Page 299 - TesaKatalogen
P. 299

U S B , D C , W i r eless P r obes                                                                              DIN 32876
                                                                                                                                                Part 1
                Wireless Probe ± 2 mm                                                                                                          Nickel-plated
                                                                                                                                                housing
                Probes developed for devices requiring a greater freedom of movement during the                                                 Stainless steel
                measurement or for parts with large dimensions.                                                                                 measuring bolt,
                Bidirectional and wireless communication synchronized with the TWIN-STATION                                                     hardened
                Receiver.                                                                                                                       Viton sealing
                –– Resolution 0,1 μm.                                                                                                           bellows = highly
                –– Range of 8 m, depending on environment.                                                                                      resistant fluoroe-
                –– TESA wireless communication protocol independent of WiFi or Bluetooth.                                                       lastomer
                –– Autonomy 40 hours (rechargeable battery).                                                                                    Fixing body nickel
                –– Mounting stem Ø 8 mm with clamping possible over entire length.                                                              Ø 8 mm
                –– Measuring bolt mounted on ball bearing.                                                                                      Stainless steel
                –– Ball bearing guide separated from mounting stem in order not to negatively                                                   measuring bolt,
                                                                                                                                                hardened and ball
                   influence the movement of the measuring bolt in the event of improper                                                        bearing guided
                   clamping of the probe body.                                                                                                  Fixed upper and
                –– Level of protection IP54 according to IEC 60529.                                                                             lower stops
                –– Wide range of measurement inserts.                                                                                           Interchangeable
                –– The TWIN-STATION (part number 05030012) manages and synchronizes up to                                                       inserts
                   8 wireless probes.                                                                                                           M2, 5 thread
                –– Interface Software TIS included in delivery content of the TWIN-STATION                                                      Carbide ball Ø 3 mm
                   (part number 05030012): display of measured values, possibility to indicate                                                  Mini jack connector
                   tolerances, simple functions +A, -A, +A+B, +A-B, and export of values ​as a .csv                                             for charger.
                   file.                                                                                                                        Mechanical max.
                Note: The sales is limited to EU countries, Switzerland, USA, Canada and China.                                                 frequency**: 60 Hz
                                                                                                                                                Power supply:
                                                                                                180.1                                           100 ÷ 240 VAC,
                                                                                                                                                50 ÷ 60 Hz; 240 mAh
                                                                       R 1,5             ø 8h6                                                  Rechargeable
                                                                                                                                                battery: 3,7 V, min.
                                                                                20.4     63.6                                             52.8  550 mAh or 800 mAh
                                                                                                                                                Frequency band:
                                                                       -2.1 +2.1                                                                2,4 GHz Range:
                                                                             0                                                                  8 m, depending on
                                                                                                                                                environment.
                                                                                                                                          10    Wireless transmis-
                                                                                                                                                sion, TWIN-STATION
                GTL 21 W                                               GTL 21 W                                                                 Receiver (05030012)
                                                                                                                                                ± 0,2 μm/°C

                                                                                                                                                20 ± 0,5°C

                                                                                                                                                Protection level
                                                                                                                                                IP54 (IEC 60529)

                                                                                                                                                GTL 21 W: 6g
                                                                                                                                                Inspection report
                                                                                                                                                with a declaration of
                                                                                                                                                conformity

                03230500 GTL 21 W          Measuring                   Nominal mea-             Bolt Sealing
                                           range, mm                   suring force*, N         retraction bellows
                                           ±2                          0,63                     Mechanical Viton

                Optional accessory:

                05030012                   TWIN-STATION Interface for wireless probes

                Max. plunger Maximum       Repeatability, Hysteresis,  Setting of lower  Cable output Data sheet
                travel, mm permissible     μm μm                       stop of                           No.
                                           0,10 0,5                    the measuring
                                error, μm                              bolt***, mm
                                (L in mm)
      GTL 21 W  4,3 0,4 + 0,8· L                                       Fixed stops: lower Without      03200602
                                                                       -2,1 upper +2,1 cable

      * Electrical zero (N) ± 25 % deviation limit. Valid in vertical mounting position, measuring bolt lowered and in static measuring.
      ** For an amplitude of 10 % to the last value of the measuring range.
      *** Distance from electrical zero.

O-26
   294   295   296   297   298   299   300   301   302   303   304