P. 301

U S B , D C , W i r eless P r obes                                                                   DIN 32876
                                                                                                                                                Part 1
                           Wireless Pneumatic Probe ± 1,5 mm                                                                                   Nickel-plated
                                                                                                                                                housing
                           Probes developed for devices requiring a greater freedom of movement during the                                      Stainless steel
                           measurement or for parts with large dimensions.                                                                      measuring bolt,
                           Bidirectional and wireless communication synchronized with the TWIN-STATION                                          hardened
                           Receiver.                                                                                                            Viton sealing
                           –– Resolution 0,1 μm.                                                                                                bellows = highly
                           –– Range of 8 m, depending on environment.                                                                           resistance fluoroe-
                           –– TESA wireless communication protocol independent from WiFi or Bluetooth                                           lastomer
                           –– Autonomy 40 hours (rechargeable battery).                                                                         Fixing body nickel
                           –– Support structure Ø 8 mm with enhanced clamping over its entire length                                            Ø 8 mm
                           –– Measuring rod mounted on ball bearing.                                                                            Stainless steel
                           –– Separate guide bearing on the holding body in order not to negatively influence                                   measuring bolt,
                                                                                                                                                hardened and ball
                              the movement of the measuring rod in the event of improper clamping of the                                        bearing guided
                              probe beads.                                                                                                      Fixed upper and
                           –– Level of protection IP54 according to IEC 60529.                                                                  lower stops
                           –– Wide range of measurement probes.                                                                                 Probe interchan-
                           –– The TWIN-STATION (part number 05030012) manages and synchronizes up                                               geable
                              to 8 wireless probes.                                                                                             M2,5 thread
                           –– Interface Software TIS included in delivery content of the TWIN-STATION                                           Carbide ball Ø 3 mm
                              (art. 05030012): display of measured values, possibility to indicate tolerances,                                  Mini jack connector
                              simple functions +A, -A, +A+B, +A-B, and export of values ​in a .csv file.                                        for charger.
                           Note: The sales is limited to EU countries, Switzerland, USA, Canada and China.                                      Mechanical max.
                                                                                                                                                frequency**: 60 Hz
                                                                                                      180.1                                     Power supply:
                                                                                                                                                100 ÷ 240 VAC,
                                                                              R 1,5          ø 8h6                                              50 ÷ 60 Hz; 240 mAh
                                                                                                                                                Rechargeable
                                                                                       20.4  63.6                                         52.8  battery: 3,7 V, min.
                                                                                                                                                550 mAh or 800 mAh
                                                                              -2.1 +2.1                                                         Frequency band:
                                                                                    0                                                           2,4 GHz Range:
                                                                                                                                                8 m, depending on
                                                                                                                                          10    environment.
                                                                                                                                                Wireless transmis-
                           GTL 212 W                                   GTL 212 W                                                                sion, TWIN-STATION
                                                                                                                                                Receiver (05030012)
                           Measuring       Nominal mea-      Bolt retraction                 Sealing  Nominal/maximal                           ± 0,2 μm/°C
                           range, mm       suring force*, N                                  bellows  pressure, bar
                           ± 1,5           1,2                                                        0,7 / max. 1,0                            20 ± 0,5°C

                                                                                                                                                Protection IP54
                                                                                                                                                (IEC 60529)

                                                                                                                                                GTL 212 W: 6g
                                                                                                                                                Inspection report
                                                                                                                                                with a declaration of
                                                                                                                                                conformity

      03230501 GTL 212                                       Pressure                        Viton
                                                             (bolt activation), spring
                                                             (bolt retraction)

      Optional accessory:

      05030012          TWIN-STATION Interface for wireless probes

      GTL 212 W  Max. meau-  Maximum       Repeatability, Hysteresis,  Setting of lower               Cable    Data sheet
                 ring bolt   permissible   μm μm                       stop of                        output   No.
                 travel, mm  error, μm     0,10 0,5                    the measuring                  Without  03200620
                 4,3         (L in mm)                                 bolt***, mm                    cable
                             0,4 + 0,8· L                              Fixed stops: lower
                                                                       -2,1 upper +2,1

      * Electrical zero (N) ± 25 % deviation limit. Valid in vertical mounting position, measuring bolt lowered and in static measuring.
      ** For an amplitude of 10 % to the last value of the measuring range.
      *** Distance from electrical zero.

O-28