DIN 32876                                      E le c t r o n i c p r obe displa y u n its – up to 2 p r obes
Part 1
                                                  TESATRONIC TT 80 and TT 90 Probe Display Units
110 mm scale length
                                                   High resolution display units
6-decade display                                   Combined analogue/digital display
plus minus sign                                    Two probe inputs for single, sum and difference measurements. 
                                                   In addition to TESATRONIC TT60 funczions, TT 80 has the following additional
12,5 x 6,6 mm                                      functions:
126 x 62 mm                                        –– 9 measuring ranges with digital steps of 0,01 μm or 0.000001 in.
LCD display,                                       –– Memorisation of extreme values "max.", "min.", "max. minus min." as well as
with 50 scale
divisions                                             the mean of the two values "max." and "min.".
Limit value for a                                  –– Dynamic measurement with acquisition of more than 10 single values per
temperature of
20°C and a relative                                   second.
humidity of                                        –– Classification of measured values with a contact relay providing output signals
≤ 50 %:
Analog display: 2 %                                   for 5, 10, 20 or 40 acceptable classes.
Digital display:                                   –– Analogue output for external processing of signals.
0,15 %                                             In addition to TESATRONIC TT60 functions, TT 90 has the following additional
Analog output:                                     functions:
0,3 %                                              –– 9 measuring ranges with digital step of 0,01 μm or 0.000001 in.
Digital output:                                    –– Memorisation of extreme values "max.", "min.", "max. minus min." plus the
0,15 %
± 1 digital interval                                  mean of both values "max." and "min.".
                                                   –– Dynamic measurement with acquisition of more than 10 single values per
255 x 235 x 120 mm
(W x D x H)                                           second. 
                                                   –– Classification of measured values with output signals through contact relay for
Resistant plastic
                                                      5, 10, 20 or 40 acceptable classes.
                                                   –– Analogue output for external signal processing.
                                                   –– Output for bolt retraction control.
                                                   –– Selection of stabilisation time for measuring cycles.
                                                   –– RS digital output for values to the micron.

                                               TT 90 TT 80

                      Application: TT 80 with  04430011  TESATRONIC TT80                    Measuring range Memory
                      a SIP (Société gene-     04430012  High precision electronic display  zoom x5
                      voise d'instruments de             TESATRONIC TT90                    –
                      physique) high preci-              High precision electronic display
                      sion measuring bench                                                  –

                                                                            Number of probes inputs  Automatic conversion of range
                                                                            2
                                               TESATRONIC TT80 High preci-
                                               sion electronic display      2
                                               TESATRONIC TT90 high preci-
                                               sion electronic display