Page 320 - TesaKatalogen
P. 320

ROHS 2 according to               E le c t r o n i c p r obe displa y u n its – up to 2 p r obes
2011/65/EU
REACH according to                   TESATRONIC TWIN-T10 probe display unit
EC 1907/2006
WEEE according to                     –– Portable display TESATRONIC TWIN-T10 for TESA inductive probe.
2002/96/EC                            –– Autonomous instrument used during assembly, on an inspection workstation
10 x 5 mm
For a temperature of                     of a production line, for final inspection or directly on a machine on the shop
20°C and a relative                      floor.
humidity of ≤ 50 %:                   –– Frequently used with a GT 31 lever probe for geometry measurements: form
Analogue and digital                     tolerances (straightness, flatness etc.) or orientation tolerances (parallelism,
response time: ≤ 100                     perpendicularity, etc.).
ms. Holding of digital                –– Function TOL for measurements with tolerances.
display: ≥ 100 ms.                    –– Memory function for values MAX, MIN or MAX-MIN for dynamic measurements.
Supply: 4 batteries                   –– Function for zero-setting of the display, for easy comparative measurements
AA 1,5 V, type LRC 6.                    with a reference part.
Power consumption:                    –– Special ZOOM mode for a more detailed visualization of the analogue scale.
≈ 7 mW/3,5 V.                            This mode simplifies the alignment and fine adjustement during assembly.
Probe supply voltage:                 Other features:
0,7 V.                                –– 4 or 7 measuring ranges from ± 5 µm to ± 5 mm, or switchable
Supply frequency:                        automatically depending on the measured value.
13 ± 0,65 kHz                         –– Access to functions by direct keys.
For a temperature of                  –– Millimetre/inch conversion.
20°C and a relative                   –– 1 probe signal input.
humidity of ≤ 50 %:                   –– Power supply by standard AA batteries.
Zero drift and signal                 –– RS232 digital output (TLC connector).
amplification:
≤ 0.005 %/° C.
Display frequency
limit with respect to
input signal: 10 Hz
IP63 (IEC 60529)
2004/ 108/EC
EN 61326-1
annex A
RS232 via TLC
connector
100 x 170 x 38 mm
(W x D x H)
LCD display size:
70 x 62 mm
500 g
(including batteries)
5 decades plus
minus sign

± 1 digital step
Value limit for a tem-
perature of 20°C and
a relative humidity of
≤ 50 %:
Analogue display:
1%
Digital display: 1 %

                                               TWIN-T10

                                  Designation            Number of probe  Automatic      Analogue       Memory func-
                                                         inputs           conversion of  scale zoom x5  tion for values
                                                                          range                         MAX, MIN,
                                                                                                        MAX-MIN

                        04430013  TESATRONIC TWIN-T10 1

                                                                                                                           O-47
   315   316   317   318   319   320   321   322   323   324   325