Page 318 - TesaKatalogen
P. 318

DIN 32876              Application:       E le c t r o n i c L e n gth M easu r i n g E q uipme n t
Part 1                 mesurement with
Hardened steel         a protected FMS  Probes with Parallel Guidance, ± 2 mm or ± 2,9 mm,
probe body,            FMS 102-P        5,8 mm Measuring Travel – Protected Version
nickel-plated
Linear guidance                         –– FMS 100-P, 102 -P, 130-P, 132-P provide dust protection of the 2 side faces.
on ball bearing.
4 M6 mounting                           Modular concept for combining elements, for example, such as springs, pneuma-
threads.. Fixed                         tic actuators and stops.
mechanical stops.                       These universal probes are suitable for mutigauging inspection fixtures as well as
Interchangeable                         machines with integrated automated inspection routines.
inserts. Holder with                    Versatility of applications:
dovetail clamping.                      –– Probe can be used in any position for measuring
Cable length: 2 m.                      –– Measuring direction can be changed
5-pin connector DIN                     –– Retraction of the measuring insert is adjustable
45322.                                  –– Measuring force is adjustable, depending on the accessory used
Supply frequency:                       –– Possibility of using off-centre measuring inserts
13 kHz (± 5 %). Max.                    Unique design:
mechanical fre-                         –– Compact assembly noted for its robustness
quency**: 25 Hz.                        –– Ball bearing guided movement
                                        –– Wide variety of measuring inserts, holders and other accessories for
-0,14 μm/°C                             –– measuring applications
                                        –– LVDT execution versions compatible with melectronic equipment from other
20 ± 0,5°C
                                           suppliers available on request.
IP54 (IEC 60529)       FMS 100-P

Mobile weight: 110 g
Inspection report
with a declaration of
conformity

                                                                    Measuring  Nominal mea-      Bolt retraction             Sealing
                                                                    range, mm  suring force*, N                              bellows
                                        03230037 FMS100-P ± 2                  2                 Retraction by air pres-     Without
                                                                                                 sure (optional)             bellows
                                        03230051 FMS130-P ± 2,9                2                 Retraction by air pres-     Without
                                                                                                 sure (optional)             bellows
                                        03230038 FMS102-P ± 2                  2                 Retraction through air      Without
                                                                                                 pressure (optional)         bellows
                                        03230052 FMS132-P ± 2,9                2                 Retraction through air      Without
                                                                                                 pressure (optional)         bellows

                                        Measuring     Max. permis- Repeatability, Hysteresis,  Setting of lower    Cable     Data sheet
                                        bolt travel,  sible errors μm          μm              stop of measuring   output    No.
                                        mm            for deviations                           bolt***, mm
                                                      in linearity,                                                Parallel  03200283
                                        5,8           μm (L en mm)                             Fixed stops: lower  Parallel  03200344
                                        5,8                                                    -2,9 upper +2,9     Angled    03200289
                       FMS100-P         5,8           0,2 + 3 · L3 0,5         0,5             Fixed stops: lower  Angled    03200345
                       FMS130-P         5,8                                                    -2,9 upper +2,9
                       FMS102-P                       0,2 + 3 · L3 0,5         0,5             Fixed stops: lower
                       FMS132-P                                                                -2,9 upper +2,9
                                                      0,2 + 3 · L3 0,5         0,5             Fixed stops: lower
                                                                                               -2,9 upper +2,9
                                                      0,2 + 3 · L3 0,5         0,5

                       * Electrical zero (N) ± 25 % deviation limit. Valid in vertical mounting position, measuring bolt lowered and in static measuring.
                       ** For an amplitude of 10 % to the last value of the measuring range.
                       *** Distance from electrical zero.

                                                                                                                                                           O-45