                                                                                                                                                                                                                                                                                                              13

                                   8
                                                                                                                                                                                                                                                                                           8

                                   M6                                                            M6
                                                                                   15 5
                5 15  30     15 5      38                               5 15  30

                      70                                                      70

                FMS 100-P                                               FMS 102-P

      Configuration and Application of TESA FMS Probes

      Shown below are the different possibilities for the activation and retraction of the probe insert during measurement
      cycles.
      Application example A

      ––Activation of the probe insert in the direc-            72      1 	 Static probe body
        tion of the part to be inspected using the                      2 	 Mobile probe body
        measuring force produced by the spring                      3   3 	 Measuring element with fine 		
        set.                                                            	adjust
                                                                        4 	 Adjustable stop
      ––Without retraction of the insert.                               5 	 Spring set for producing
                                                                        	 measuring force
      Result A                                                          6 	 M6 mounting thread
      During the placing of a new part to be                            7 	 Holder
      measured, the measuring insert remains in
      its contact position thanks to the measuring    4      6  1   65

      force produced by the spring set.

      Application example B

      ––Activation of the probe insert in the direc-  98                                  5 	 Spring set for producing
        tion of the part to be measured using the                                         	 measuring force
        measuring force of the spring set.                                                8 	Pneumatique actuator
                                                                                          	 (Part No. 03260440)
      ––Retraction of the insert by pneumatic                                             9 	 Connector (Part No. 024388))
        pressure through a pneumatic connection.
                                                                        5
      Result B
      During the placing of a new part to be
      measured, the measuring insert is retracted
      through activation of pressure via the pneu-
      matic actuator.

      Application example C

      ––Activation of the probe insert in the             5                               5 	 Spring set for producing
        direction of the part to be inspected by                                           	 measuring force
        pneumatic pressure and the measuring                                              8 	Pneumatic actuator
        force of the spring set.                                                           	 (Part No. 03260440)
                                                                                          9 	 Connector (Part No. 024388)
      ––Retraction of the insert by disabling the                                         10 	Auxiliary spring element
        pneumatic pressure.                                                                	 (Part No. 03260445)

      ATTENTION !                                                       10 8 9
      The force of the spring set (5) must be equal
      to that of the auxiliary spring element (10).
      Result C
      During the placing of a new part to be
      measured, the measuring insert is automa-
      tically retracted due to the disabling of the
      pneumatic pressure. which guarantees about
      security during the measuring cycle.

      This configuration is typically preferred when
      there is lack of space for connecting a pneu-
      matic actuator (left side of example B).