E le c t r o n i c L e n gth M easu r i n g E q uipme n t

DIN 32876              Application: Minimal      Probes with Parallel Guidance, ± 2 mm or ± 2,9 mm,
Part 1                 space usage with FMS      5,8 mm Measuring Travel
Hardened steel         units placed side by
probe body,            side                      Modular construction enables the combination of elements, for example, such as
nickel-plated                                    springs, pneumatic cylinders and stops.
Linear guidance on                               These universal probes are suited for multigauging fixtures as well as machines
ball bearing. 4 M6                               equipped with integrated inspection routines.  
mounting threads.                                Versatility of applications:
Fixed mechanical                                 –– Probe can be used in any position for measuring.
stops. Interchan-                                –– Measuring direction is adjustable.
geable inserts.                                  –– Retraction of the measuring insert is adjustable.
Dovetail.clamp for                               –– Measuring force is adjustable depending on the accessory used.
mounting holder.                                 –– Possibility of using off-centre measuring inserts.
Cable length: 2 m.                               Unique design:
5-pin connector DIN                              –– Compact assembly noted for its robustness.
45322.                                           –– Ball bearing guided movement.
Supply frequency:                                –– Wide variety of measuring inserts, holders and other accessories for
13 kHz (± 5 %) Max.
mechanical                                          measuring applications.
frequency**: 25 Hz.                              –– LVDT execution versions compatible with melectronic equipment from other

-0,14 μm/°C                                         suppliers available on request.

20 ± 0,5°C

IP50 (IEC 60529)

Mobile weight: 110 g   Application: small
Inspection report      component measuring
with a declaration of  thanks to offset inserts
conformity

                                                 FMS 100                                          FMS 102

                                                 03230019 FMS 100    Measuring  Nominal mea-      Bolt retraction          Sealing
                                                 03230049 FMS 130    range, mm  suring force*, N                           bellows
                                                 03230028 FMS 102    ±2         2                 Retraction by air pres-
                                                 03230050 FMS 132                                 sure (optional)          Without
                                                                     ± 2,9      2                 Retraction by air pres-  bellows
                                                                                                  sure (optional)          Without
                                                                     ±2         2                 Retraction by air pres-  bellows
                                                                                                  sure (optional)          Without
                                                                     ± 2,9      2                 Retraction by air pres-  bellows
                                                                                                  sure (optional)          Without
                                                                                                                           bellows

                                Measuring        Max.permis- Repeatabilty, Hysteresis, Setting of lower Cable output Data sheet
                                bolt travel,     sible error for μm             μm stop of mea-                            No.
                                mm               deviation in                        suring bolt***,
                                5,8              linearity, μm                       mm
                                5,8              (L in mm)
                                5,8
                       FMS 100  5,8              0,2 + 3 · L3 0,5               0,5  Fixed stops: Parallel                 03200253
                       FMS 130                                                       lower -2,9 upper
                       FMS 102                                                       +2,9
                       FMS 132
                                                 0,2 + 3 · L3 0,5               0,5  Fixed stops: Parallel                 03200342
                                                                                     lower -2,9 upper
                                                                                     +2,9

                                                 0,2 + 3 · L3 0,5               0,5  Fixed stops: Parallel                 03200254
                                                                                     lower -2,9 upper
                                                                                     +2,9

                                                 0,2 + 3 · L3 0,5               0,5  Fixed stops: Parallel                 03200343
                                                                                     lower -2,9 lower
                                                                                     +2,9

                       * Electrical zero (N) ± 25 % deviation limit. Valid in vertical mounting position, measuring bolt lowered and in static measuring.
                       ** For an amplitude of 10 % to the last value of the measuring range.
                       *** Distance from electrical zero.