Page 316 - TesaKatalogen
P. 316
E le c t r o n i c L e n gth M easu r i n g E q uipme n t
DIN 32876 Application: Minimal Probes with Parallel Guidance, ± 2 mm or ± 2,9 mm,
Part 1 space usage with FMS 5,8 mm Measuring Travel
Hardened steel units placed side by
probe body, side Modular construction enables the combination of elements, for example, such as
nickel-plated springs, pneumatic cylinders and stops.
Linear guidance on These universal probes are suited for multigauging fixtures as well as machines
ball bearing. 4 M6 equipped with integrated inspection routines.
mounting threads. Versatility of applications:
Fixed mechanical –– Probe can be used in any position for measuring.
stops. Interchan- –– Measuring direction is adjustable.
geable inserts. –– Retraction of the measuring insert is adjustable.
Dovetail.clamp for –– Measuring force is adjustable depending on the accessory used.
mounting holder. –– Possibility of using off-centre measuring inserts.
Cable length: 2 m. Unique design:
5-pin connector DIN –– Compact assembly noted for its robustness.
45322. –– Ball bearing guided movement.
Supply frequency: –– Wide variety of measuring inserts, holders and other accessories for
13 kHz (± 5 %) Max.
mechanical measuring applications.
frequency**: 25 Hz. –– LVDT execution versions compatible with melectronic equipment from other
-0,14 μm/°C suppliers available on request.
20 ± 0,5°C
IP50 (IEC 60529)
Mobile weight: 110 g Application: small
Inspection report component measuring
with a declaration of thanks to offset inserts
conformity
FMS 100 FMS 102
03230019 FMS 100 Measuring Nominal mea- Bolt retraction Sealing
03230049 FMS 130 range, mm suring force*, N bellows
03230028 FMS 102 ±2 2 Retraction by air pres-
03230050 FMS 132 sure (optional) Without
± 2,9 2 Retraction by air pres- bellows
sure (optional) Without
±2 2 Retraction by air pres- bellows
sure (optional) Without
± 2,9 2 Retraction by air pres- bellows
sure (optional) Without
bellows
Measuring Max.permis- Repeatabilty, Hysteresis, Setting of lower Cable output Data sheet
bolt travel, sible error for μm μm stop of mea- No.
mm deviation in suring bolt***,
5,8 linearity, μm mm
5,8 (L in mm)
5,8
FMS 100 5,8 0,2 + 3 · L3 0,5 0,5 Fixed stops: Parallel 03200253
FMS 130 lower -2,9 upper
FMS 102 +2,9
FMS 132
0,2 + 3 · L3 0,5 0,5 Fixed stops: Parallel 03200342
lower -2,9 upper
+2,9
0,2 + 3 · L3 0,5 0,5 Fixed stops: Parallel 03200254
lower -2,9 upper
+2,9
0,2 + 3 · L3 0,5 0,5 Fixed stops: Parallel 03200343
lower -2,9 lower
+2,9
* Electrical zero (N) ± 25 % deviation limit. Valid in vertical mounting position, measuring bolt lowered and in static measuring.
** For an amplitude of 10 % to the last value of the measuring range.
*** Distance from electrical zero.